20% OFF shipping at adviceperu.com on orders over $79 + up to 10% OFF products
adviceperu.com
home > Yokogawa VM1S Analog I/O Module | New & Original Stock > Yokogawa VM1S Analog I/O Module | New & Original Stock
download picture
Yokogawa VM1S Analog I/O Module | New & Original StockYokogawa VM1*S Multipoint Analog I O Module The Yokogawa VM1*S, also cataloged as the VM1*S Multipoint Analog Input Output Card, operates as a dedicated hardware component for precise analog signal processing and data acquisition within CENTUM VP and CENTUM CS 3000 platforms. Hardware Specifications Parameter Specification Model VM1*S Brand Yokogawa Origin Japan Weight 0. 6 kg Dimensions 5. 1 cm x 17. 8 cm x 7. 6 cm Operating Temp 40 to +70 deg C
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Yokogawa VM1*S Multipoint Analog I/O Module

The Yokogawa VM1*S, also cataloged as the VM1*S Multipoint Analog Input/Output Card, operates as a dedicated hardware component for precise analog signal processing and data acquisition within CENTUM VP and CENTUM CS 3000 platforms.

Hardware Specifications

Parameter Specification
Model VM1*S
Brand Yokogawa
Origin Japan
Weight 0.6 kg
Dimensions 5.1 cm x 17.8 cm x 7.6 cm
Operating Temp -40 to +70 deg C
Power Consumption 3.5 W
Module Type Multipoint Input/Output Module / High-Speed Data Acquisition Board
Channel Capacity Up to 12 analog/digital channels
Signal Input Envelopes Voltage (0-10 V), Current (4-20 mA), TC (K,J,E,T,R,S,B,N,WRe,PLII), RTD (Pt100,JPt100,Ni100), Contact
Sampling Rate Up to 100 ms per channel
Data Storage Internal flash memory (~400 MB) + Integrated SD card slot
Communication Interfaces Ethernet (10/100BASE-T) with HART Communication Functionality
Redundancy Options Configurable for dual-redundancy
Integrated Display 5.7-inch color TFT LCD

Process Control & DCS Instrumentation Properties

The Yokogawa VM1*S incorporates built-in 4-20 mA HART loop protocol routing to facilitate digital variable pass-through directly from field transmitters to central DCS processing layers. The component integrates channel-to-channel isolation circuits to mitigate ground loop propagation and eliminate cross-talk anomalies across distributed instrument clusters. When deployed in high-availability loops, the module utilizes a software-configurable dual-redundancy matrix to achieve zero-latency backup transitions if the primary data acquisition board undergoes a hardware interrupt or diagnostics fault.

Frequently Asked Questions

Q: How is the channel conversion timing managed during peak multiplexing routines?

A: The board operates on an internal deterministic clock, driving high-speed data acquisition at up to 100 ms sampling intervals per channel. This rapid sampling prevents signal skew when processing mixed current, voltage, thermocouple, and resistance temperature detector (RTD) inputs simultaneously.

Q: What are the primary flash memory limitations during localized data logging runs?

A: The card contains approximately 400 MB of internal storage space. For logging applications spanning long-term recording intervals, an external industrial SD card must be fitted into the designated hardware slot to prevent local buffer overwrite conditions.

Q: Can this module process temperature inputs natively without secondary external signal conditioners?

A: Yes, the onboard conversion electronics feature cold junction compensation (CJC) to interpret direct thermocouple connections, alongside high-impedance source tracking for Pt100 and JPt100 RTD elements via user-defined calibration parameters.

Field Installation Guidelines

  • Chassis Attachment Verification: Insert the module into the designated slot on the CENTUM rack interface. Tighten the integral mechanical fasteners to ensure full backplane connector engagement and secure a low-impedance ground connection to the chassis frame.
  • HART / Analog Cable Shielding: Wire all analog I/O loops with individual twisted, shielded pairs. Connect the shield drain wires exclusively to the marshalling cabinet instrumentation ground bus; do not bond the shield at the field-device housing to prevent current induction.
  • Signal Classification Separations: Maintain physical separation between the low-voltage sensor inputs (such as millivolt thermocouples or 4-20 mA links) and high-voltage AC utility distribution cables within the wire management trays.
  • Channel Profile Matching: Before executing the application loop, verify through the system configuration builder that each channel parameters match the physical sensor type attached to the field terminal blocks to avoid measurement drift or open-circuit diagnostics.

Yokogawa VM1S Analog I/O Module | New & Original Stock

Item no : 24307503520
sold recently : Login >>
US$ 99.00
Pay in 4 interest-free payments of $24.75 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 20 - Jun 25

Enjoy 20% off shipping

US$ 99.00

1-11

US$ 89.10

12-35

US$ 69.30

36-59

US$ 59.40

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches