Premium shielded riser-rated 6-conductor security alarm cable engineered for complex multi-zone installations requiring both EMI protection and heavy-duty performance. This USA-made cable features six 18-gauge stranded bare copper conductors with 7 strands each, protected by aluminum foil shielding and housed in a CMR-rated gray jacket. Combining heavy-duty 18 AWG construction with multi-conductor versatility and complete shielding, this cable represents the optimal choice for professional commercial installations requiring maximum capability in non-plenum spaces.
Key Features
-
18 AWG 6-Conductor Configuration - Heavy-duty wire gauge with multi-zone capability
-
Aluminum Foil Shielding - Superior protection against electromagnetic interference (EMI/RFI)
-
7-Strand Bare Copper Conductors - Excellent flexibility and reliable signal transmission
-
CMR/CL3R Riser Rated (FT4) - Approved for vertical shaft and in-wall installations
-
Low-Smoke PVC Construction - Enhanced fire safety with reduced smoke emission
-
Sequential Footage Marking - Precise measurement for accurate installation planning
-
Print Legend for Identification - Cable markings save valuable installation time
-
ETL Listed & RoHS Compliant - Meets strict safety and environmental standards
-
Gray PVC Jacket - Professional appearance for visible installations
-
Made in USA - Premium domestic manufacturing quality
Ideal Applications
Perfect for shielded multi-zone riser installations in commercial buildings:
- Multi-Zone Security & Alarm Systems
- Commercial Access Control Systems
- Professional Intercom Systems
- Multi-Zone Audio Distribution
- Power-Limited Control Circuits
- Building Automation in EMI Environments
- Long-Run Commercial Installations
Technical Specifications
-
Conductor Material: Stranded Bare Copper
-
Wire Gauge: 18 AWG
-
Number of Conductors: 6
-
Strands per Conductor: 7
-
Conductor Insulation: 0.010" PVC
-
Shielding: Aluminum Foil (100% Coverage)
-
Cable Diameter (Nominal OD): 5.84mm (0.230")
-
Jacket Thickness: 0.38mm (0.015")
-
Jacket Material: Low-Smoke PVC
-
Jacket Color: Gray
Electrical Performance
-
Maximum Temperature: 75°C (167°F)
-
Voltage Rating: 300V
-
Center Resistance: 21.20 Ω/km
Certifications & Compliance
-
Riser Rating: CMR (Communications Riser)
-
Fire Rating: FT4
-
Additional Ratings: CL3R, FPLR
-
Listings: ETL Listed
-
Environmental: RoHS Compliant
-
NEC Article Compliance:
- 22-16 AWG: FPLR/760, CMR/800, CL3R, CL2R/725
- 14-12 AWG: FPLR, CL3R
Package Details
-
Length: 1000 feet per spool
-
Country of Origin: Made in USA
-
Special Features: Print legend for easy identification
Why Choose Shielded 18/6 Riser Cable?
✓ Triple Advantage - Heavy-duty 18 AWG + 6 conductors + EMI shielding
✓ Maximum Performance - Longest cable runs (up to 3,000 feet) with multi-zone capability
✓ EMI/RFI Protection - Aluminum foil shielding prevents interference and false alarms
✓ Multi-Zone Capability - Six conductors support 3 independent circuits
✓ Fire Code Compliant - CMR/FT4 riser rating for vertical installations
✓ Professional Quality - Print legend markings save installation time
✓ Future-Proof - Extra conductors available for system expansion
✓ Cost-Effective - Consolidates up to 3 separate shielded cable runs
Riser Installation Requirements
Use CMR Riser Cable When:
- Installing vertically between floors
- Running through walls and vertical shafts
- Non-plenum spaces in commercial buildings
- Multi-story residential or commercial installations
- Building codes require fire-rated cable (but not plenum)
Note: Riser (CMR) cable is suitable for most commercial and residential applications except air-handling plenum spaces. For plenum spaces, use CMP-rated cable instead.
FT4 Fire Rating Explained
FT4 Rating is the Canadian equivalent of the CMR riser rating:
-
Same fire safety performance as CMR
- Recognized in Canadian building codes
-
Fully interchangeable with CMR-rated cable
-
Suitable for vertical installations in both US and Canadian buildings
-
Low flame spread characteristics
Common Use Cases
-
Multi-Story Office Buildings: Multi-zone security with vertical riser runs between floors
-
Commercial Complexes: Large buildings requiring long cable runs with EMI protection
-
Industrial Facilities: Security systems in manufacturing environments with heavy machinery
-
Warehouse Security: Perimeter protection with multiple zones and long cable runs
-
Retail Centers: Multi-zone security with EMI protection from electronic equipment
-
Educational Institutions: Multi-building campus security with integrated systems
-
Healthcare Facilities: Multi-zone security near medical equipment (EMI protection critical)
-
Data Centers: Multi-zone security with EMI protection near servers and networking
-
Parking Structures: Multi-level security with long vertical runs
-
Government Buildings: Critical security installations requiring heavy-duty construction
Installation Best Practices
-
Grounding: Ground aluminum foil shield at ONE end only (typically at control panel) to prevent ground loops
-
Separation: Maintain minimum 6-inch separation from AC power lines when possible
-
Bend Radius: Maintain minimum 10x cable diameter bend radius (approximately 2.3 inches)
-
Termination: Use proper shielded connectors and maintain shield continuity to ground
-
Shield Handling: Be careful not to tear or damage the foil shield during installation
-
Testing: Test all 6 conductors for continuity, shorts, and proper shield grounding
-
Vertical Support: Support cable appropriately for vertical riser installations per NEC
-
Labeling: Document which conductor pairs are used for which circuits
-
Fire Stopping: Use riser-rated fire stop materials at floor penetrations
-
Pulling Tension: Do not exceed 25 lbs maximum pulling tension to avoid shield damage
-
Print Legend: Use cable markings for verification and documentation
EMI Protection in Commercial Environments
Common Sources of EMI in Commercial Buildings:
- HVAC motors and variable frequency drives
- Elevator systems and motors
- Fluorescent and LED lighting systems
- Computer servers and networking equipment
- Copy machines and office equipment
- Point-of-sale terminals
- Industrial machinery and equipment
- Power transformers and electrical panels
How EMI Affects Multi-Zone Systems:
- False alarms from multiple zones simultaneously
- Intermittent signal issues across circuits
- Cross-talk between conductor pairs
- Unreliable device communication
- Increased service calls and maintenance costs
Shielding Solution: Aluminum foil shielding provides a protective barrier around all 6 conductors, intercepting electromagnetic waves before they induce currents in any of the signal pairs. This ensures reliable multi-zone operation even in the most electrically noisy commercial environments.
When to Choose This Cable
Perfect For:
- Multi-zone commercial security with long cable runs (1,500-3,000 feet)
- Professional installations requiring both heavy-duty and multi-conductor
- Vertical riser installations in multi-story buildings with EMI concerns
- Integrated security systems combining alarm, intercom, and access control
- Commercial/industrial environments with significant electrical interference
- Projects where consolidating multiple systems into one cable saves labor
- Installations where future expansion is anticipated
Consider Alternatives If:
- Plenum spaces required (choose 18/6 shielded plenum instead)
- Short runs under 1,500 feet (20/6 or 22/6 may be adequate)
- Minimal EMI concerns (18/6 unshielded may suffice)
- Single or two-zone application (18/2 or 18/4 may be better value)
- Budget constraints with simpler requirements
Technical Advantages Summary
-
18 AWG Conductors: Heavy-duty professional grade for maximum run lengths
-
6-Conductor Design: Multi-zone capability with three independent circuits
-
Aluminum Foil Shield: 100% coverage protects all conductors from EMI/RFI
-
7-Strand Construction: Superior flexibility despite larger wire gauge
-
Riser Rating: CMR/FT4 approved for vertical installations
-
Low-Smoke Jacket: Fire safety compliance for commercial buildings
-
Print Legend: Quick identification saves installation and service time
-
Sequential Marking: Precise footage tracking for professional installation
-
ETL Listed: Third-party safety certification ensures quality
Building Code Compliance
Before Installation:
- Verify riser rating is adequate (not plenum spaces)
- Confirm NEC article compliance for specific application
- Check equipment manufacturer specifications
- Consult with authority having jurisdiction (AHJ)
- Ensure proper fire stopping at floor penetrations
This cable meets or exceeds:
- National Electrical Code requirements
- CMR/FT4 riser fire safety standards
- ETL safety certification standards
- RoHS environmental compliance
- Local building code requirements (verify jurisdiction)