Shopping security
The NC6 Patient Monitor from Comen is designed for precise monitoring of vital signs. It reliably measures respiratory rate, temperature, blood pressure and SpO2, ensuring comprehensive and accurate patient monitoring.
With its compact and portable design, the monitor is ideal for flexible use in diverse clinical settings.The large, easy-to-read display and intuitive interfaces implify operation, enabling even less experienced staff to work confidently with the device. Thanks to its fast and accurate monitoring technology, it provides precise blood pressure readings in under 15 minutes, while the non-invasive temperature measurement ensures accurate results.
The device's modern Bluetooth and Wi-Fi connectivity allows for seamless integration with existing systems and simple data transfer, enhancing the efficiency of patient information management. Additionally, the monitor stores up to 240 hours of trend data, facilitating detailed analysis of vital signs over extended periods.
Easy operation via button control ensures that all functions can be used efficiently and with minimal effort. This is particularly advantageous in emergency situations or during postoperative monitoring.
| Dimensions | 260 x 150 x 250 mm |
| Weight | Approx. 3.5 kg |
| Display Size | 8 inches |
| Screen Resolution | 1024 x 768 pixels |
| Power Supply | 100-240 V, 50/60 Hz |
| NIBP (Non-Invasive Blood Pressure Measurement) | |
| Measurement Method | Oscillometry, Inflation and Deflation |
| Standard | IEC 80601-2-30 |
| Modes | Manual, Interval, Clock, Sequence, STAT, Orthostatic BPP, NIBP Average |
| Parameters | Systolic, Diastolic, Mean Value, Heart Rate |
| Typical Measurement Time | Approx. 15 seconds |
| Maximum Measurement Time | Adults/Children approx. 120 seconds Newborns approx. 85 seconds |
| Measurement Interval | 1-720 minutes, adjustable |
| Measurement Unit | mmHg/kPa, selectable |
| Measurement Range (Static) | 0-300 mmHg (0-40.0 kPa) |
| Accuracy | ±3 mmHg (±0.4 kPa) |
| Resolution | 1 mmHg |
| Venous Puncture | Yes |
| SpO2 Measurement | |
| Standard | ISO 80601-2-61 |
| Measurement Range | Comen/Nellcore: 0-100% Masimo: 1-100% |
| Resolution | 1% |
| Accuracy | Adults/Children: ±2% (70-100%) Newborns: ±3% (70-100%) |
| Alarm Range | 1-100% |
| Perfusion Index (PI) | Yes, with Comen & Masimo |
| Alarm Volume | Adjustable |
| Response Time | Under 30 seconds |
| Dual SpO2 Function | Yes, SpO2, SpO2b, ΔSpO2 (Brand should be the same) |
| Heart Rate | |
| Measurement Range | Comen NIBP: 30-300 bpm Comen SpO2: 20-300 bpm Masimo SpO2: 25-240 bpm Nellcore SpO2: 20-300 bpm |
| Respiratory Rate | |
| Measurement Range | 4-70 rpm |
| Accuracy | ±3 rpm |
| Resolution | 1 rpm |
| Measurement Duration | ≤30 seconds |
| Update Time | 1 second |