Enterprise-grade plenum-rated 10-conductor security alarm cable engineered for the most complex multi-zone and integrated building systems. This USA-made cable features ten 18-gauge stranded bare copper conductors with 7 strands each, housed in a low-smoke CMP-rated white jacket. Designed for sophisticated security systems, intercoms, audio distribution, and building automation where maximum conductor count, heavy-duty construction, and fire safety compliance are essential.
Key Features
-
18 AWG 10-Conductor Configuration - Maximum versatility for enterprise-grade integrated systems
-
Heavy-Duty 18 AWG Wire Gauge - Lower resistance for extended cable runs and higher current capacity
-
7-Strand Bare Copper Conductors - Superior flexibility and reliable signal transmission
-
CMP/CL3P Plenum Rated - Approved for HVAC plenums and air-handling spaces
-
Low-Smoke PVC Construction - Enhanced fire safety with minimal toxic smoke emission
-
10 Color-Coded Conductors - Complete color spectrum for easy identification (Black, Red, White, Green, Brown, Blue, Orange, Yellow, Purple, Gray)
-
Sequential Footage Marking - Precise measurement for accurate installation planning
-
ETL Listed & RoHS Compliant - Meets strict safety and environmental standards
-
White Low-Smoke Jacket - Clean, professional appearance for visible installations
-
Made in USA - Premium domestic manufacturing quality
Ideal Applications
Perfect for enterprise-level plenum installations requiring maximum flexibility:
- Large-Scale Multi-Zone Security Systems
- Enterprise Access Control & Building Management
- Campus-Wide Integrated Security Solutions
- Commercial Intercom & PA Systems
- Multi-Zone Audio Distribution Systems
- Building Automation & HVAC Controls
- Critical Infrastructure & Government Facilities
- Smart Building Integration
Technical Specifications
-
Conductor Material: Stranded Bare Copper
-
Wire Gauge: 18 AWG
-
Number of Conductors: 10
-
Strands per Conductor: 7
-
Conductor Insulation: 0.009" Low-Smoke PVC
-
Cable Diameter (Nominal OD): 7.26mm (0.286")
-
Jacket Thickness: 0.457mm (0.018")
-
Jacket Material: Low-Smoke PVC
-
Jacket Color: White
-
Shielding: Unshielded
Electrical Performance
-
Maximum Temperature: 75°C (167°F)
-
Voltage Rating: 300V
Certifications & Compliance
-
Plenum Rating: CMP (Communications Plenum)
-
Additional Ratings: CL3P, FPLP
-
Listings: ETL Listed
-
Environmental: RoHS Compliant
-
NEC Article Compliance:
- 22-16 AWG: FPLP/760, CMP/800, CL3P, CL2P/725
- 14-12 AWG: FPLP, CL3P
Conductor Color Coding (10 Colors)
- Black
- Red
- White
- Green
- Brown
- Blue
- Orange
- Yellow
- Purple
- Gray
Jacket Printing
18 AWG 10C UNSHIELDED TYPE CL3P/FPLP c(ETL)us TYPE CMP 3054355
Package Details
-
Length: 1000 feet per spool
-
Country of Origin: Made in USA
Why Choose 18/10 Plenum Cable?
✓ Maximum Conductor Count - Ten conductors provide ultimate flexibility for complex integrated systems
✓ Heavy-Duty Construction - 18 AWG supports longer runs (up to 30% longer than 22 AWG)
✓ Fire Code Compliant - CMP plenum rating meets stringent requirements for air-handling spaces
✓ Low Smoke Safety - Special insulation reduces toxic emissions during fire emergencies
✓ Future-Proof Design - Extra conductors accommodate system expansion without re-cabling
✓ Professional Installation - Complete 10-color coding streamlines complex installations
✓ Versatile Integration - Single cable supports multiple systems simultaneously
✓ Cost-Effective - Consolidates up to 5 separate 2-wire circuits in one cable run
18/10 Configuration Advantages
Why Choose 10 Conductors with 18 AWG?
Conductor Count Comparison:
-
2-Conductor: Single circuit or zone
-
4-Conductor: 2 independent circuits
-
6-Conductor: 3 independent circuits
-
8-Conductor: 4 independent circuits
-
10-Conductor: 5 independent circuits - MAXIMUM VERSATILITY
18 AWG Advantages:
-
40% lower resistance than 22 AWG
-
Longer cable runs - up to 3,000+ feet for most systems
-
Higher current capacity - supports powered devices like magnetic locks
-
Reduced voltage drop - maintains system performance over distance
-
Professional grade - preferred for commercial and industrial applications
Typical 18/10 Configurations:
- 5 independent alarm zones (2 wires each)
- 3 security zones + 2 intercom circuits
- 2 security zones + 2 intercom + 1 access control circuit
- Multiple integrated systems with room for future expansion
- Complex building automation with multiple control loops
Common Use Cases
-
Enterprise Campuses: University or corporate campus-wide security with multiple buildings
-
Large Commercial Buildings: Multi-floor office buildings with integrated security and access control
-
Healthcare Facilities: Hospital security, nurse call, and building automation integration
-
Government Buildings: Critical infrastructure with multiple security zones and access levels
-
Educational Institutions: School security with classroom intercoms and emergency notification
-
Industrial Complexes: Manufacturing facilities with perimeter security and process control
-
Shopping Centers: Mall security with multiple tenant zones and central monitoring
-
Hotels & Resorts: Guest room security, access control, and in-room services
-
Multi-Tenant Buildings: Separate security systems for each tenant with central management
-
Smart Buildings: Complete integration of security, HVAC, lighting, and access control
-
Data Centers: Multi-zone security with environmental monitoring and access control
-
Transportation Hubs: Airport or train station security with public address integration
Installation Best Practices
-
Planning: Map out all circuits before installation; document which colors are assigned to which systems
-
Color Coding: Use consistent color assignments throughout the installation for easy troubleshooting
-
Bend Radius: Maintain minimum 10x cable diameter bend radius (approximately 2.8 inches)
-
Separation: Keep minimum 6-inch separation from AC power lines when possible
-
Pulling Tension: Do not exceed 25 lbs maximum pulling tension to avoid conductor damage
-
Support: Support cable every 4.5 feet in horizontal runs, every 6 feet in vertical runs
-
Termination: Strip carefully to avoid nicking conductors; use proper crimp or screw terminals
-
Testing: Test all 10 conductors for continuity and shorts before final connection
-
Labeling: Label both ends of cable clearly with circuit assignments
-
Fire Stopping: Use plenum-rated fire stop materials at all penetrations
-
Documentation: Create comprehensive wiring documentation for future service and expansion
When Shielding is NOT Required
This cable is unshielded, making it ideal when:
- EMI/RFI interference is minimal or not a concern
- Cable runs are separated from high-voltage power lines
- Budget considerations favor unshielded solutions
- Building has low electromagnetic interference
- Systems are not prone to false alarms from electrical noise
If your environment has:
- Heavy machinery or industrial equipment
- High-density electrical installations
- Long parallel runs with AC power
- History of EMI-related false alarms
Consider: 18/8 Shielded Plenum Cable instead for maximum EMI protection
Color-Coding System Benefits
10-Color Configuration Provides:
-
Zero Confusion: Unique color for each conductor eliminates wiring errors
-
Easy Troubleshooting: Quickly trace specific circuits by color
-
Professional Installation: Color consistency throughout large projects
-
Future Service: Technicians can immediately identify circuit assignments
-
Multi-System Support: Different colors for different systems (e.g., Red/Black for security, Blue/Brown for intercom)
-
Documentation: Easier to create clear wiring diagrams and schematics
Standard Industry Color Assignments (typical):
-
Black/Red: Primary security zone
-
White/Green: Secondary security zone
-
Brown/Blue: Intercom or audio circuit
-
Orange/Yellow: Access control or auxiliary
-
Purple/Gray: Expansion or special functions
Technical Advantages Summary
-
18 AWG Conductors: Heavy-duty gauge for professional installations with long runs
-
10-Conductor Design: Maximum flexibility for complex integrated systems
-
7-Strand Construction: Superior flexibility for routing through conduits and tight spaces
-
Plenum Rating: CMP approved for air-handling spaces nationwide
-
Low-Smoke Jacket: Enhanced fire safety meets strictest building codes
-
Complete Color Coding: All 10 conductors uniquely identified for error-free installation
-
ETL Listed: Third-party safety certification ensures quality and compliance
-
Made in USA: Domestic manufacturing ensures consistent quality
Value Proposition
This 18/10 plenum cable is the ultimate choice for:
-
Complex Projects: Installations requiring maximum conductor count and flexibility
-
Professional Integrators: Systems requiring heavy-duty construction and long runs
-
Future-Proofing: Buildings where system expansion is anticipated
-
Code Compliance: Projects requiring plenum-rated cable for fire safety
-
Quality Assurance: Installations where reliability and performance are critical
Cost Justification:
-
Labor Savings: One cable pull instead of 5 separate runs
-
Material Reduction: Fewer individual cables, less conduit required
-
Future Value: Extra conductors available for expansion without re-cabling
-
Professional Results: Clean installation with comprehensive color coding
-
Long-Term Reliability: Heavy-duty 18 AWG construction ensures years of service
When to Choose This Cable
Perfect For:
- New construction with plenum space requirements
- Large commercial or institutional facilities
- Complex multi-zone security installations
- Integrated building management systems
- Projects requiring maximum flexibility and future expansion
- Professional installations demanding heavy-duty construction
- Long cable runs requiring 18 AWG performance
Consider Alternatives If:
- Simple 1-4 zone residential system (22/4 may suffice)
- High EMI environment (consider shielded cable)
- Non-plenum spaces where riser cable is acceptable
- Budget constraints with simpler system requirements
- Short cable runs under 500 feet
The 18/10 plenum configuration represents the ultimate in unshielded security alarm cable design - maximum conductors, heavy-duty construction, and complete fire safety compliance for the most demanding commercial and institutional installations.