NF ZM2371 100 kHz LCR MeterNF ZM2371 100 kHz LCR Meter Key Features At A Glance Measurement frequency spanning 1 mHz to 5. 5 MHz across the series Eight measurement ranges from 100 m to 1 M with automatic or manual range selection 0. 08% basic measurement accuracy Primary and secondary parameters including Z , Y , L, C, R, G with auto parameter and equivalent circuit (parallel series auto) selection Constant voltage and constant current (ALC) drive with internal DC bias and
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NF ZM2371 100 kHz LCR Meter

Key Features At A Glance

  • Measurement frequency spanning 1 mHz to 5.5 MHz across the series
  • Eight measurement ranges from 100 mΩ to 1 MΩ with automatic or manual range selection
  • 0.08% basic measurement accuracy
  • Primary and secondary parameters including |Z|, |Y|, L, C, R, G with auto parameter and equivalent-circuit (parallel/series/auto) selection
  • Constant-voltage and constant-current (ALC) drive with internal DC bias and auto-selected output impedance
  • USB (USBTMC), RS-232, and GPIB (IEEE 488) standard, with optional LAN (10BASE-T/100BASE-TX) for ATE integration
  • Open, short, load, and cable-length correction plus four-point contact check
  • Built-in comparator with bin sorting and an optically isolated handler interface for production sorting

An LCR meter measures the inductance (L), capacitance (C), and resistance (R) of passive components by applying a known AC test signal and analyzing the resulting impedance. The ZM2371, ZM2372, and ZM2376 are bench LCR meters that report both primary parameters — |Z|, |Y|, L, C, R, and G — and secondary parameters including Q, D, θ, X, B, Rs, Rp, Lp, and Rdc, with parallel, series, or automatic equivalent-circuit selection.

Across the series, primary and secondary parameters can be selected automatically, and each instrument displays the voltage applied to the device under test alongside the current flowing through it. A built-in comparator evaluates measurements against multiple limit conditions — up to 32 steps for total comparison — and drives an optically isolated handler interface whose BIN outputs support sorting of components in automated handling systems.

ValueTronics stocks and holds its own inventory in a 20,000-square-foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments we list are on hand and ready to ship.

Compare Other Models in This Series

The ZM2371, ZM2372, and ZM2376 form a family of LCR meters that share a common measurement architecture — eight measurement ranges from 100 mΩ to 1 MΩ, 0.08% basic accuracy, constant-voltage/constant-current drive, and a full set of correction functions — while differing primarily in maximum measurement frequency and comparator bin capacity.

All three models present the same primary and secondary parameters and the same standard remote-control interfaces, so the choice among them centers on the measurement frequency range and the sorting capacity an application requires.

Each model below links to its own dedicated product page with new-condition pricing. Select the specific model that matches your measurement frequency and sorting requirements to see its current availability and price.

The ZM2376 extends the measurement frequency to 5.5 MHz — the widest in this family — offers a wider internal DC bias setting range, and is supplied with IVI drivers for instrument-control environments.

The most significant difference across the family is maximum measurement frequency: the ZM2371 and ZM2372 cover settings up to 100 kHz, while the ZM2376 extends to 5.5 MHz. The ZM2376 also offers a wider internal DC bias setting range and is supplied with IVI drivers, whereas the ZM2371 and ZM2372 include a LabVIEW driver.

The models also differ in comparator bin capacity and in physical depth and weight. Refer to the comparison table below for the exact figures per model.

Model Max. Measurement Frequency Frequency Resolution Max. Internal DC Bias
ZM2371 100 kHz 5 digits +2.50 V
ZM2372 100 kHz 5 digits +2.50 V
ZM2376 5.5 MHz 6 digits +5 V

Additional differences in specifications beyond the few shown above are not listed here — see each model's full specifications below.

Accessories Supplied

  • Power cord set (3-pole, 2 m)
  • Instruction manual
  • CD-ROM (application software, sample program)
  • LabVIEW driver

Product Core & Specifications

Specification Value
Measurement Parameters
Primary parameters |Z|, |Y|, L, C, R, G (for equivalent circuit of L, C, R: Parallel / Series / Auto Selection selectable)
Secondary parameters Q, D, θ, X, B, Rs, Rp, G, Lp, Rdc
Auto parameter selection Primary parameters (including equivalent circuit) and secondary parameters can be selected automatically
Measured Value Display Range
|Z|, R (Rs, Rp, Rdc), X 0Ω, ±(0.001 mΩ to 999.999 MΩ)
|Y|, G, B 0S, ±(0.01 nS to 9.99999 kS)
C (Cp, Cs) 0F, ±(0.00001 pF to 999.999 kF)
L (Ls, Lp) 0H, ±(0.001 nH to 99.9999 GH)
Q, D 0, ±(0.00001 to 99999.9)
θ ±180.000 deg
Measurement Conditions
Measurement frequency Setting range: 1 mHz to 100 kHz, Resolution 5 digits (1 mHz when < 10 Hz); Accuracy: ±0.01%
Measurement signal level 10 mVrms to 5.00 Vrms, Resolution 3 digits (1 mVrms when < 100 mVrms), RMS values at open output; Accuracy: ±(10% + 5 mVrms)
Constant voltage / Constant current mode (ALC) Constant voltage / Constant current / Disabled. Voltage setting range: 10 mVrms to 5.00 Vrms, Resolution 3 digits (<100 mVrms: 1 mVrms); Current setting range: 1 µArms to 200 mArms, Resolution 3 digits (<10 µArms: 0.1 µArms)
Output impedance 5Ω / 25Ω / 100Ω, automatically selected according to the measurement range
Internal DC bias Setting range: 0 V to +2.50 V, Resolution: 0.01 V, Accuracy: ±(5% + 3 mV). Can be turned on/off at open output
Trigger source INT (internal automatic continuous), MAN (manual), EXT (handler interface), BUS (remote control)
Trigger delay time Setting range: 0.000 s to 999.999 s, Resolution: 0.001 s (time after trigger input until start of signal acquisition)
Triggered drive Selectable: Drive only at measurement / Continuous drive
Measurement speed RAPid / FAST / MEDium / SLOW / VerySLOw
Measurement Range
Ranges 8 ranges (1 MΩ, 100 kΩ, 10 kΩ, 1 kΩ, 100 Ω, 10 Ω, 1 Ω, 100 mΩ)
Range selection Auto / Manual
Measurement Accuracy
Basic accuracy 0.08% (refer to appendix)
Other Measurement Functions
Correction function Open, Short, Load and Cable Length
Contact check Detects a contact failure at four contact points; additional time 4 ms (reference)
Averaging 1 to 256 times
Deviation measurement Primary/secondary parameters: deviation and deviation % from reference value can be displayed
Comparator Primary parameters: Max. 9 bins; Secondary parameters: upper limit and lower limit comparison; original measured value / deviation / deviation % can be sorted
Handler interface All I/O signals are optically isolated (withstand voltage ±42 V). Input: Trigger, Key lock, Settings/correction value memory designation. Output: BIN1 to BIN11, NC/BIN12, PHI/BIN13, PLO/BIN14, OUT OF BINS, S-NG, ERR, INDEX, EOM
Multi-measurement Execute measurement and limit comparison under multiple conditions for the total comparison; maximum number of steps: 32
Monitor display Voltage value applied to the DUT and current value flowing in the DUT
Remote Control Interfaces
USB USBTMC, USB1.1 Full-speed
RS-232 Data rate: 4800 bps to 230400 bps
GPIB Conforms to IEEE 488.1 and IEEE 488.2 Standards
LAN (optional) 10BASE-T, 100BASE-TX
General Specifications
Power supply AC 100 V to 230 V ±10% (but 250 V or less); Frequency 50/60 Hz ±2 Hz; Overvoltage category II; Power consumption: 70 VA or less
Operating environment Temperature 0 to +40 °C; Humidity 5 to 85% RH (absolute humidity 1 to 25 g/m³, non-condensing)
Storage environment Temperature -10 to +50 °C; Humidity 5 to 95% RH (absolute humidity 1 to 29 g/m³, non-condensing)
Pollution degree Pollution degree 2 (indoor use)
Settings/correction value memory 32 sets; settings and correction values can be saved and restored individually or together
Resume Last setting and correction value are restored at power-on
External dimensions 260 (W) × 88 (H) × 220 (D) mm (not including protuberances)
Weight (without accessories) Approx. 2.0 kg
Important: Specified measurement accuracy assumes a warm-up of 30 minutes or more, open and short zero correction, cable-length correction per the connection cable length, and a one-year calibration cycle.
Important: The standard supplied accessories (power cord set, instruction manual, CD-ROM/drivers) do not include a measurement fixture or test leads. A connection cable/fixture appropriate to the DUT is required to perform measurements; the datasheet's cable-length correction supports cable lengths of 0 m, 1 m, 2 m and 4 m.
Important: The LAN interface (10BASE-T / 100BASE-TX) is an option and is not fitted on the standard model.

About this New unit

This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.

ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.

Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

NF ZM2371 100 kHz LCR Meter

Item no : 29944709687
sold recently : Login >>
US$ 950.00
Pay in 4 interest-free payments of $237.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 950.00

1-11

US$ 855.00

12-35

US$ 665.00

36-59

US$ 570.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches