The Lepu Medical PC-3000 Multi-Parameter Patient Monitor is a sophisticated vital signs monitoring device. Featuring a high-resolution 7-inch colour TFT display, user-friendly interface, and comprehensive monitoring parameters including ECG, SpO2, Blood Pressure, Respiration, Temperature and Pulse Rate, it is ideal for hospitals and clinical facilities. The monitor offers various NIBP measurement modes, including Manual, Auto, and STAT, catering to adults, children, and newborns.
With the capability to store data from 12,000 blood pressure measurements and 2,000 arrhythmia events, the device provides extensive data recording. ECG waveforms can be stored for up to 60 hours and trend data is accessible for over 1,000 hours. Display options include waveform or extra-large digits for optimal readability. Additionally, the device is equipped with visual and audible alarms to indicate critical conditions.
| Display | 7-inch colour TFT display (800 x 480 Pixels) |
| Weight | 3 kg |
| Battery | Rechargeable lithium battery |
| Alarm Functions | Acoustic & visual |
| Operating Conditions | Temperature: 5 - 40 °C Humidity: 15 - 85% (non-condensing) |
| Storage Conditions | Temperature: -20 - 60 °C Humidity: 10 - 95% |
| ECG | |
| Input Signal Range | ± 0.5 - 5mVp |
| Heart Rate Display Range | 15 - 350 bpm (for adults and children) |
| Accuracy | ± 1% or ± 2bpm |
| Response Time | From 80 bpm to 120 bpm: < 8 seconds From 80 bpm to 40 bpm: < 8 seconds |
| Large T-Wave Suppression | Suppresses T-Waves with ≤ 120% of 1mV QRS Value |
| Pacemaker Pulse Suppression | Suppresses Pulses with Amplitude ±2mV to ±700mV and Duration of 0.1 to 2 ms without exceeding |
| Noise Level | ≤30 μVP-P |
| Respiration | |
| Measurement Range | 0 - 120 rpm |
| Accuracy | ±5% or ±2 rpm |
| Temperature | |
| Measurement Range | 21 - 50.0 °C |
| Measurement Accuracy | ±0.2 ℃ for a range of 25℃ to 45℃, 0.4 ℃ for other ranges |
| Response Time | < 150 seconds |
| Minimum Measurement Duration | > 130 seconds |
| Measurement Site | Body surface |
| Units | °C and °F |
| SpO2 | |
| Probe | LED with dual wavelength |
| Measurement Range | 0 - 100% |
| Measurement Accuracy | 2% for an SpO2 range of 70 - 100% (according to ISO 80601-2-61) |
| Alarm Range | High: 1 - 100% Low: 0 - 99% |
| NIBP | |
| Measurement Method | Oscillometric method |
| NIBP Pneumatic Pressure Measurement Range | 0 - 300 mmHg |
| Accuracy | +3 mmHg |
| Measurement Duration | < 30 seconds (adult cuff) |
| Cuff Inflation Start Pressure | Adult: < 150 mmHg Child: < 120 mmHg Newborn: < 70 mmHg |
| Tolerance | +5 mmHg |
| Overpressure Protection Limit | Adult: 300 mmHg Child: 240 mmHg Newborn: 150 mmHg |
| Accuracy | Max. Mean Difference: +5 mmHg Max. Standard Deviation: 8 mmHg |
| Measurement Modes | Manual, Auto, STAT |