The Megger AVO210 is a general purpose digital multimeter offering AC and DC voltage and current measurements alongside resistance, frequency and capacitance ranges. Its simplified functions are designed to avoid continual reference to the user guide, and the supplied test leads use GS38-compliant shrouded tips.
A digital multimeter is the foundational handheld diagnostic instrument on an electrical bench, combining voltage, current, resistance and related measurements in a single tool. The AVO210 is suited to electricians, heating engineers and alarm technicians, with additional features that extend it across a wide range of applications.
ValueTronics stocks and holds its own inventory in a 20,000 square foot secure warehouse at 1675 Cambridge Drive in Elgin, Illinois, so the instruments listed here are equipment we keep on hand rather than source on demand.
| Specification | Value |
|---|---|
| General | |
| Display | 2000 counts |
| Polarity | Automatic, positive implied, negative indicated |
| Over-range indication | “OL” or “-OL” |
| Battery indicator | “<” is displayed when the batteries voltage drops below operating voltage |
| Auto power down | Approx 10 minutes |
| Operating ambient | Non-condensing ≤10 °C, 11 °C ~ 30 °C (≤80% R.H) 31 °C ~ 40 °C (≤75% R.H), 41 °C ~ 50 °C (≤45% R.H) |
| Storage temperature range and humidity | -20 °C to 60 °C, 0 to 80% R.H. when battery removed from meter |
| Temperature co-efficient | 0.15 x (Spec. Accy.) / °C, < 18 °C or > 28 °C |
| Sample rate | Samples 2 times per second nominal |
| Maximum altitude | 6561.7 ft (2000 m) |
| Safety | Complies with EN61010-1, UL61010-1, IEC 61010-1; V/Ω CAT III 600 V, CAT II 1000 V; A CAT III 500 V |
| Pollution degree | 2 |
| Power supply | 1.5 V x 2 LR03 or AAA size |
| Battery life | Alkaline 250 hours |
| Dimensions | 74 mm x 156 mm x 44 mm |
| Weight | 320 g |
| AC/DC Volts (Accuracy ± (% reading + number of digits) at 23 °C ± 5 °C < 80%RH) | |
| AC 200.0 mV | Unspecified |
| AC 2.000 V | ±(1.5%+5 dgts) 50 Hz ~ 300 Hz |
| AC 20.00 V ~ 200.0 V | ±(1.5%+5 dgts) 50 Hz ~ 500 Hz |
| AC 750 V / DC 1000 V | ±(1.5%+5 dgts) 50 Hz ~ 500 Hz |
| DC Accuracy | ±(0.5% + 2 dgts) |
| Over voltage protection | 1000 V DC or 750 V AC rms |
| Input Impedance | 10 MΩ // less than 100 pF |
| CMRR (VAC) | > 60 dB at DC, 50 Hz / 60 Hz |
| CMRR (VDC) | > 100 dB at DC, 50 Hz / 60 Hz |
| NMRR | > 50 dB at DC, 50 Hz / 60 Hz |
| AC conversion type | Average sensing rms indication. AC conversions are ac-coupled, true rms responding, calibrated to the sine wave input. |
| Crest Factor additional error | +1.5% for C.F. from 1.4 to 3; +3% for C.F. from 3 to 4 |
| DC/AC Current | |
| 2.000 A — DC Accuracy | ±(1.0% + 3 dgts) |
| 2.000 A — AC Accuracy | ±(1.5% + 5 dgts) |
| 2.000 A — Voltage Burden | 2 V max |
| 10.00 A — DC Accuracy | ±(1.0% + 3 dgts) |
| 10.00 A — AC Accuracy | 50 Hz ~ 500 Hz |
| 10.00 A — Voltage Burden | 2 V max |
| Overload protection (A input) | 10 A (500 V) fast blow fuse |
| Ampere testing duty ratio | 10 A: 1 min test / 10 min rest; 9 A: 2 min / 10 min; 8 A: 3 min / 10 min; 7 A: 4 min / 10 min; 6 A: 5 min / 10 min; 5 A: continually / N/A |
| Resistance | |
| 200.0 Ω ~ 200.0 KΩ | ±(0.7% + 3 dgts), 2 V max |
| 2.000 MΩ | ±(1.0% + 3 dgts), 2 V max |
| 20.00 MΩ | ±(1.5% + 3 dgts), 2 V max |
| Open circuit voltage | -1.3 V approx |
| Diode Check | |
| Resolution | 10 mV |
| Accuracy | ±(1.5% + 5 dgts) |
| Frequency | |
| 2000 Hz ~ 200.0 KHz | Sensitivity >1.5 Vac rms, <5 Vac rms; Accuracy 0.01% ±1 digit |
| 2.000 MHz ~ 20.00 MHz | Sensitivity >2 Vac rms, <5 Vac rms; Accuracy 0.01% ±1 digit |
| Capacitance | |
| 2.000 nF ~ 200.0 µF | ±(1.9% + 8 dgts), Overload Protection 600 V rms |
| 2.000 mF | ±(1.9% + 8 dgts), Overload Protection 600 V rms |
| Input impedance | 10 MΩ // less than 100 pF |
Important: Ampere testing duty ratio: 10 A measurements are limited to 1 minute of testing followed by 10 minutes of rest, while 5 A and below may be measured continually.
Important: 10 A current testing is duty-cycle limited: 10 A is rated for 1 minute on / 10 minutes rest, with longer test times permitted only at lower currents (5 A may be applied continually).
This is a brand-new, factory-sealed unit, supplied exactly as it arrives from the manufacturer and backed by the full manufacturer warranty. For the exact configuration, available options, included accessories, or current lead time for your application, our Test Architects can confirm the details before you order.
ValueTronics supplies both new and used test and measurement equipment. New units ship factory-sealed, exactly as received from the manufacturer; every used unit is inspected and functionally verified in-house at our 20,000 sq ft secure facility in Elgin, Illinois before it ships. Our Test Architects can help you select the condition, calibration, and configuration that fit your application.
Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.
Ships within 48 hours · Estimated delivery Jun 22 - Jun 27
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order